RI-EM42
RI-EM42 is I/O extension module for PRO-series gateways.
Features
Type
Pulse counting
- Digital input can function as 0/1 binary input or pulse counter (eg. for water or gas meter).
- Operation mode is configurable via cloud platform.
- 64 bit unsigned integer is used to store up to 18 446 744 073 709 551 616 pulses.
Relay outputs
Ratings |
|
Voltage AC |
230 [V] |
Voltage DC |
24 [V] |
Current |
5 [A] |
Connection diagram
See Smart Extension Port for wiring, cable requirements and more information.
LED Status indicator
LED continuous signals table
Colour |
Signal |
When |
Description |
Green |
Continuous |
During operation |
Normal operation |
Red |
Continuous |
During operation |
Error detected |
LED blink signals table
Colour |
Signal |
Number of blinks |
Length |
When |
Description |
Yellow |
Blink |
1 |
100 [ms] |
During operation |
IO action performed |
Yellow |
Blink |
25 |
100 [ms] |
During startup |
Factory reset init |
Yellow |
Blink |
1 |
1000 [ms] |
After factory reset init |
Factory reset begun |
Yellow |
Blink |
3 |
1000 [ms] |
After factory reset begun |
Factory complete |
Terminal blocks
- 5 mm raster.
- max 2.5 mm2 (24-12 AWG).
TOP
DIN1 |
DIN2 |
GND |
DIN3 |
DIN4 |
GND |
|
|
|
|
|
|
BOTTOM
NO1 |
COM1 |
NC1 |
NO2 |
COM2 |
NC2 |
|
|
|
|
|
|